Exin CDCS Exam Dumps PDF

EXIN EPI Certified Data Centre Specialist

Total Questions: 120
Update Date: July 16, 2026

PDF + Test Engine $65
Test Engine $55
PDF $45

  • Last Update on July 16, 2026
  • 100% Passing Guarantee of CDCS Exam
  • 90 Days Free Updates of CDCS Exam
  • Full Money Back Guarantee on CDCS Exam

DumpsFactory is forever best for your Exin CDCS exam preparation.

For your best practice we are providing you free questions with valid answers for the exam of Exin, to practice for this material you just need sign up to our website for a free account. A large bundle of customers all over the world is getting advantages by our Exin CDCS dumps. We are providing 100% passing guarantee for your CDCS that you will get more high grades by using our material which is prepared by our most distinguish and most experts team.

Most regarded plan to pass your Exin CDCS exam:

We have hired most extraordinary and most familiar experts in this field, who are so talented in preparing the material, that there prepared material can succeed you in getting the high grades in Exin CDCS exams in one day. That is why DumpsFactory available for your assistance 24/7.

Easily accessible for mobile user:

Mobile users can easily get updates and can download the Exin CDCS material in PDF format after purchasing our material and can study it any time in their busy life when they have desire to study.

Get Pronto Exin CDCS Questions and Answers

By using our material you can succeed in Exin CDCS exam in your first attempt because we update our material regularly for new questions and answers for Exin CDCS exam.

Notorious and experts present Exin CDCS Dumps PDF

Our most extraordinary experts are too much familiar and experienced with the behaviour of Exin Exams that they prepared such beneficial material for our users.

Guarantee for Your Investment

DumpsFactory wants that their customers increased more rapidly, so we are providing to our customer with the most demanded and updated questions to pass Exin CDCS Exam. You can claim for your investment by using our money back policy if you have not been availed with our promised facilities for the Exin exams. For details visit to Refund Contract.

Question 1

The logical overview of the data center looks as pictured. To what TIA-942 Rating is this design made based on electrical only?

A. Rating - 4
B. Rating - 3
C. Rating - 2
D. Rating - 1

Answer: A

Question 2

You are allowed to use a calculator for this question. The total power consumption of the ICT equipment in a rack is 6 kW. The equipment is traditional ICT equipment with a Delta-T of approximately 11 °C / 20 °F. Calculate the approximate CFM required to cool the equipment in the rack. 

A. Approximately 1,500 CFM
B. Approximately 1,000 CFM
C. Approximately 500 CFM
D. Approximately 160 CFM

Answer: B

Question 3

What indicates the breaking capacity of a fuse or breaker? 

A. Mechanical strength of the casing of a fuse or breaker.
B. The maximum voltage, in case of an electrical surge, that the fuse or breaker can handle withoutbeing destroyed or causing an electric damaging arc.
C. The current at which the device will trip.
D. The current that a fuse or breaker is able to interrupt without being destroyed or causing anelectric damaging arc.

Answer: D

Question 4

The computer room has high levels of H2S gas contamination. What is the best option to resolve this issue?

A. Vacuum the whole room using a HEPA/S-Class-based filter.
B. Install air-scrubbers.
C. Clean the room and racks with a damp/wet cloth.
D. Provide more air changes per hour by adding more fresh air to the computer room.

Answer: B

Question 5

You are allowed to use a calculator for this question. A battery bank is rated at a total capacity of 600 Ah. Calculate how much charging current the rectifier should be able to supply as charging current.

A. 12 Amperes
B. 30 Amperes
C. 60 Amperes
D. 80 Amperes

Answer: B

Question 6

In order to save energy, you are going to install an automated system to switch off lights. What should be taken into consideration when installing such a system?

A. Security guards should perform regular inspections verifying the system works.
B. The system should not be based on motion detection as the lights might suddenly switch off while staff is still at work.
C. It is not advisable to use such a system since it will reduce the lifetime of LED lighting. 
D. At all times, the levels should allow for security cameras to function properly. 

Answer: D

Question 7

You are allowed to use a calculator for this question.A computer room has a net volume of approximately 2,500 m³ / 88,287 ft³.The temperature is 20 °C / 68 °F.The required design concentration is 7%.The S-Factor is 0.1359 (metric) / 1.885 (imperial).Calculate the amount of gas required for this computer room based on FM200. What is the correctweight?

A. Approximately 410 kg / 900 lbs
B. Approximately 820 kg / 1,800 lbs
C. Approximately 1,390 kg / 3,000 lbs
D. Approximately 1,640 kg / 3,600 lbs

Answer: B

Question 8

What should be considered when installing overhead data cabling? 

A. To maintain minimum separation from power and ensure that the fire detection and suppressionsystems are not hindered.
B. Copper data cabling should not be placed in metal cable trays.
C. Optical fiber cabling should always be positioned on top of the copper cabling in the same cabletray to avoid damage to the sensitive optical fiber.
D. All cabling should make sharp bends directly into the rack to avoid usage of additional space andblocking the airflow on top of the rack.

Answer: A

Question 9

You are changing the design of the fire suppression system for your computer room from ahalocarbon fire suppression system into an inert-based fire suppression system. Could you use thesame formula to calculate the gas content for the gas?

A. No, there is a significant difference in the formula for the different types of fire suppression gases.
B. Yes, as long as you take the difference between the net and gross volume into account.
C. Yes, as long as you use the same units of measure, i.e., kg/m³ or lbs/ft³.
D. Yes, as long as you change the 'S' factor of the formula to reflect the gas type used.

Answer: A

Question 10

What is the main disadvantage of using a ToR (Top of Rack) design? 

A. A single ToR (Top of Rack) switch is more expensive than an EoR (End of Row) switch.
B. You need a separate rack to install all your ToR (Top of Rack) switches.
C. There will be more switches to manage. 
D. A ToR (Top of Rack) switch has only optical interfaces.

Answer: C